{"id":2587,"date":"2026-10-16T07:36:41","date_gmt":"2026-10-16T07:36:41","guid":{"rendered":"https:\/\/www.swgjcamera.com\/?p=2587"},"modified":"2026-10-16T07:36:43","modified_gmt":"2026-10-16T07:36:43","slug":"how-to-choose-an-explosion-proof-camera-for-hazardous-areas","status":"publish","type":"post","link":"https:\/\/www.swgjcamera.com\/fr\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/","title":{"rendered":"How to Choose an Explosion-Proof Camera for Hazardous Areas"},"content":{"rendered":"<h2 class=\"wp-block-heading\">What is an explosion-proof camera?<\/h2>\n\n\n\n<p>An explosion-proof camera is surveillance equipment designed for use in locations where flammable gas, vapor, dust or other combustible material may create an explosive atmosphere. Its protective construction is intended to prevent the equipment from becoming an ignition source under the conditions covered by its certification and installation method.<\/p>\n\n\n\n<p>This is different from simply using a weatherproof outdoor camera. An IP rating addresses protection against ingress of dust and water; it does not, by itself, prove suitability for a classified hazardous area. A project must evaluate the protection concept, certification marking, equipment group, temperature class, installation accessories, cable entries, power supply and maintenance procedure together.<\/p>\n\n\n\n<p>SWGJ CAMERA presents a product range that includes explosion-proof PTZ cameras, fixed bullet cameras, dome cameras, thermal-imaging products and explosion-proof accessories. The company website positions these products for demanding environments such as petrochemical, oil and gas, coal mining, marine, electricity, chemical and other industrial applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">When does a facility need an explosion-proof camera?<\/h2>\n\n\n\n<p>An explosion-proof camera may be required when the camera will be installed in a classified area identified by the facility&#8217;s hazardous-area assessment. Typical locations can include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Oil and gas exploration sites<\/li>\n\n\n\n<li>Refineries and petrochemical processing units<\/li>\n\n\n\n<li>Chemical production and storage areas<\/li>\n\n\n\n<li>Gas stations and fuel-handling areas<\/li>\n\n\n\n<li>Coal mines and other mining environments<\/li>\n\n\n\n<li>Grain processing and storage facilities where combustible dust is present<\/li>\n\n\n\n<li>Offshore platforms and marine industrial facilities<\/li>\n\n\n\n<li>Paint, ink and other flammable-material processing areas<\/li>\n<\/ul>\n\n\n\n<p>The camera should not be selected from the industry name alone. The responsible electrical, process-safety or hazardous-area engineer should confirm the classification at the exact mounting position and define the required equipment protection level.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How do you select the right explosion-proof camera type?<\/h2>\n\n\n\n<p>The camera type should follow the monitoring task first, then the certification and installation requirements.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">Camera type<\/th><th class=\"has-text-align-left\" data-align=\"left\">Typical monitoring task<\/th><th class=\"has-text-align-left\" data-align=\"left\">Main selection question<\/th><\/tr><\/thead><tbody><tr><td>Explosion-proof fixed bullet camera<\/td><td>Wellheads, pumps, valves, entrances and defined equipment points<\/td><td>What fixed field of view and identification detail are required?<\/td><\/tr><tr><td>Explosion-proof dome camera<\/td><td>Confined rooms, corridors, cabins and locations needing a compact form<\/td><td>Is the housing size, lens angle and mounting clearance suitable?<\/td><\/tr><tr><td>Explosion-proof PTZ camera<\/td><td>Tank farms, drilling floors, pipe racks and wide process areas<\/td><td>Is long-range zoom, preset patrol or remote inspection required?<\/td><\/tr><tr><td>Dual-sensor thermal camera<\/td><td>Heat-anomaly observation, fire-risk awareness and low-visibility monitoring<\/td><td>What thermal resolution, measurement and alarm functions are actually required?<\/td><\/tr><tr><td>Varifocal or integrated-zoom camera<\/td><td>Installations where the final viewing distance may change<\/td><td>Can the lens be adjusted without compromising the certified assembly?<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>A large site may need more than one camera type. Fixed cameras can provide stable views of critical points, while a PTZ camera can inspect a wider area. A thermal camera can add another detection channel, but it should not be described as a gas detector unless the complete system has a suitable gas-detection function and supporting evidence.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">When should you choose an explosion-proof PTZ camera?<\/h2>\n\n\n\n<p>Choose an explosion-proof PTZ camera when operators need to inspect multiple directions or distant assets from a protected control location. PTZ cameras can be useful for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Large tank farms<\/li>\n\n\n\n<li>Drilling floors and derrick areas<\/li>\n\n\n\n<li>Long pipe corridors<\/li>\n\n\n\n<li>Offshore decks<\/li>\n\n\n\n<li>Wide process units<\/li>\n\n\n\n<li>Perimeter areas around industrial equipment<\/li>\n<\/ul>\n\n\n\n<p>The SWGJ&nbsp;<a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-ptz-camera\/infrared-ptz\/\" target=\"_blank\" rel=\"noreferrer noopener\">Explosion-Proof Infrared PTZ Camera<\/a>&nbsp;page describes a PTZ product with continuous horizontal rotation, vertical movement, infrared night vision and optical zoom. The same page displays both series-level ranges and a parameter table for a specific configuration. Therefore, buyers should request the exact model datasheet rather than assuming that every listed resolution, zoom value, temperature range or interface applies to every PTZ unit.<\/p>\n\n\n\n<p>Before choosing a PTZ camera, confirm:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Required horizontal and vertical coverage<\/li>\n\n\n\n<li>Optical zoom and target distance<\/li>\n\n\n\n<li>Preset, patrol and automatic-tracking functions<\/li>\n\n\n\n<li>Night-vision method and usable range<\/li>\n\n\n\n<li>Mounting bracket and structural load<\/li>\n\n\n\n<li>Power and network transmission method<\/li>\n\n\n\n<li>Maintenance access and cleaning requirements<\/li>\n\n\n\n<li>Exact certification marking for the selected model<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">When is a fixed explosion-proof camera better?<\/h2>\n\n\n\n<p>A fixed camera is often more appropriate when the monitoring target is known and should remain continuously visible. Examples include a valve, pump, wellhead, gate, loading point, control access or a defined section of a production line.<\/p>\n\n\n\n<p>The SWGJ&nbsp;<a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-bullet-camera\/fixed-lens\/\" target=\"_blank\" rel=\"noreferrer noopener\">Explosion-Proof Fixed Lens Camera<\/a>&nbsp;page lists 2MP and 4MP product options, fixed-lens choices, infrared or dual-light configurations, IP68 protection, PoE\/DC power options and explosion-protection markings. These are useful selection categories, but the final project must verify the exact model and its approved configuration.<\/p>\n\n\n\n<p>A fixed camera can offer several practical benefits:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Stable and predictable field of view<\/li>\n\n\n\n<li>Continuous observation of a critical asset<\/li>\n\n\n\n<li>Simpler commissioning than a multi-position PTZ<\/li>\n\n\n\n<li>Easier comparison of image coverage before and after installation<\/li>\n\n\n\n<li>Lower dependence on operator presets and patrol schedules<\/li>\n<\/ul>\n\n\n\n<p>The correct lens is important. A wide lens may cover more area but provide less detail at a distant point. A narrower lens may improve target detail but create blind areas around the camera.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">When should you choose an explosion-proof dome camera?<\/h2>\n\n\n\n<p>A compact dome camera can be useful in locations where space is restricted or where a low-profile housing is preferred. The SWGJ&nbsp;<a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-dome-camera\/fixed-dome\/\" target=\"_blank\" rel=\"noreferrer noopener\">Explosion Proof Fixed Dome<\/a>&nbsp;page describes a mini dome direction for confined hazardous spaces such as industrial corridors, elevators and offshore or industrial cabins.<\/p>\n\n\n\n<p>Check the following before choosing a dome camera:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Available ceiling or wall space<\/li>\n\n\n\n<li>Required field of view<\/li>\n\n\n\n<li>Lens and infrared clearance<\/li>\n\n\n\n<li>Impact and vibration exposure<\/li>\n\n\n\n<li>Access for cleaning and inspection<\/li>\n\n\n\n<li>Cable-entry direction and fitting compatibility<\/li>\n\n\n\n<li>Clearance around the housing for maintenance<\/li>\n<\/ul>\n\n\n\n<p>A compact housing should not be confused with a universal installation solution. The mounting surface, bracket, cable entry and certified accessories still need to be approved for the project.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What is the role of thermal imaging?<\/h2>\n\n\n\n<p>Thermal imaging detects differences in infrared radiation and can help operators identify heat patterns that may not be visible in ordinary video. In industrial surveillance, this may support monitoring of equipment temperature, process areas or potential heat anomalies.<\/p>\n\n\n\n<p>The SWGJ&nbsp;<a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-ptz-camera\/dual-sensor-thermal\/\" target=\"_blank\" rel=\"noreferrer noopener\">Explosion Proof Dual Sensor Thermal Camera<\/a>&nbsp;page describes a visible-light and thermal-imaging combination, with product information covering heat-anomaly observation, fire-risk awareness, PTZ movement and stainless-steel housing options.<\/p>\n\n\n\n<p>Before specifying a thermal camera, ask for the exact technical evidence:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Thermal detector resolution<\/li>\n\n\n\n<li>Spectral range<\/li>\n\n\n\n<li>Temperature measurement range<\/li>\n\n\n\n<li>Measurement accuracy and calibration conditions<\/li>\n\n\n\n<li>Alarm threshold configuration<\/li>\n\n\n\n<li>Thermal and visible-light alignment<\/li>\n\n\n\n<li>Recording and event-output method<\/li>\n\n\n\n<li>Performance in smoke, fog, rain and reflective environments<\/li>\n\n\n\n<li>Certification scope of the complete product assembly<\/li>\n<\/ul>\n\n\n\n<p>Avoid treating every thermal camera as a certified fire-detection or gas-leak-detection device. Those functions depend on the model, configuration, algorithms, installation conditions and applicable project requirements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How should you verify ATEX or IECEx information?<\/h2>\n\n\n\n<p>Certification verification should be based on the exact equipment and certificate, not only on a logo or a marketing sentence.<\/p>\n\n\n\n<p>The EU&#8217;s&nbsp;<a href=\"https:\/\/eur-lex.europa.eu\/eli\/dir\/2014\/34\/oj\/eng\" target=\"_blank\" rel=\"noreferrer noopener\">ATEX Directive 2014\/34\/EU<\/a>&nbsp;concerns equipment and protective systems intended for use in potentially explosive atmospheres. The IECEx system explains that its certified equipment scheme uses independent third-party testing and evaluation for equipment intended for explosive atmospheres; its&nbsp;<a href=\"https:\/\/www.iecex.com\/certified-equipment-scheme\/overview\/\" target=\"_blank\" rel=\"noreferrer noopener\">Certified Equipment Scheme overview<\/a>&nbsp;provides the official context.<\/p>\n\n\n\n<p>For a camera purchase, request and check:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>The exact product model covered by the certificate<\/li>\n\n\n\n<li>The full explosion-protection marking<\/li>\n\n\n\n<li>Equipment group and category or level<\/li>\n\n\n\n<li>Gas or dust group<\/li>\n\n\n\n<li>Temperature class or maximum surface temperature<\/li>\n\n\n\n<li>Ambient-temperature range<\/li>\n\n\n\n<li>Certificate number and issuing body<\/li>\n\n\n\n<li>Permitted cable glands, conduit and accessories<\/li>\n\n\n\n<li>Installation, inspection and maintenance instructions<\/li>\n\n\n\n<li>Any limitations, suffixes or conditions of safe use<\/li>\n<\/ol>\n\n\n\n<p>The marking should be interpreted by a qualified person who understands the project&#8217;s applicable regulations. A certificate for a camera housing does not automatically certify an unrelated junction box, flexible tube, bracket, power supply or cable gland.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why do installation accessories matter?<\/h2>\n\n\n\n<p>The camera body is only one part of a hazardous-area surveillance system. A project may also require an approved bracket, junction box, cable gland, flexible tube, conduit, grounding connection, power equipment and network transmission path.<\/p>\n\n\n\n<p>SWGJ CAMERA lists&nbsp;<a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-accessories\/\" target=\"_blank\" rel=\"noreferrer noopener\">Explosion-Proof Accessories<\/a>&nbsp;including a&nbsp;<a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-accessories\/junction-box\/\" target=\"_blank\" rel=\"noreferrer noopener\">Certified Junction Box<\/a>,&nbsp;<a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-accessories\/flexible-tube\/\" target=\"_blank\" rel=\"noreferrer noopener\">Flameproof Flexible Tube<\/a>&nbsp;and camera bracket products.<\/p>\n\n\n\n<p>The accessory plan should verify:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Thread and cable-entry compatibility<\/li>\n\n\n\n<li>Material and corrosion resistance<\/li>\n\n\n\n<li>Protection rating<\/li>\n\n\n\n<li>Certification and conditions of use<\/li>\n\n\n\n<li>Cable bending and mechanical support<\/li>\n\n\n\n<li>Grounding and bonding<\/li>\n\n\n\n<li>Power, network, alarm and audio interfaces<\/li>\n\n\n\n<li>Maintenance access<\/li>\n<\/ul>\n\n\n\n<p>A flexible tube should protect and route the cable; it should not be assumed to carry the camera&#8217;s structural load. The bracket and supporting structure must be designed for the camera weight and environmental forces.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How should you match the camera to the site environment?<\/h2>\n\n\n\n<p>A hazardous-area camera must also survive the non-electrical conditions of the site. Review:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ambient temperature and temperature changes<\/li>\n\n\n\n<li>Salt spray and marine corrosion<\/li>\n\n\n\n<li>Chemical exposure<\/li>\n\n\n\n<li>Dust and water ingress<\/li>\n\n\n\n<li>Vibration and mechanical impact<\/li>\n\n\n\n<li>Wind loading and mounting height<\/li>\n\n\n\n<li>Cleaning, washdown and inspection requirements<\/li>\n\n\n\n<li>Lighting, fog, smoke and glare<\/li>\n\n\n\n<li>Available power and data transmission<\/li>\n<\/ul>\n\n\n\n<p>The SWGJ website presents 304 stainless steel as a standard material direction on several product pages and describes 316 stainless steel as an available option on selected products. This should be confirmed for the exact model and project environment; material availability is not automatically the same as certificate scope or suitability for every chemical exposure.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What should be included in an explosion-proof camera project plan?<\/h2>\n\n\n\n<p>A complete project plan should contain:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">Planning document<\/th><th class=\"has-text-align-left\" data-align=\"left\">What it should define<\/th><\/tr><\/thead><tbody><tr><td>Hazardous-area drawing<\/td><td>Classification at each camera position<\/td><\/tr><tr><td>Camera schedule<\/td><td>Model, lens, viewing target and mounting point<\/td><\/tr><tr><td>Certification register<\/td><td>Certificate, marking, model and conditions of safe use<\/td><\/tr><tr><td>Network diagram<\/td><td>Camera, switch, fiber, wireless or control-room connections<\/td><\/tr><tr><td>Power diagram<\/td><td>Voltage, protection, backup power and isolation<\/td><\/tr><tr><td>Accessory schedule<\/td><td>Brackets, glands, junction boxes, flexible tubes and conduit<\/td><\/tr><tr><td>Storage plan<\/td><td>Recording platform, retention, resolution and export method<\/td><\/tr><tr><td>Commissioning checklist<\/td><td>Image, PTZ, night view, alarm, recording and network tests<\/td><\/tr><tr><td>Maintenance plan<\/td><td>Inspection frequency, cleaning, seal checks and approved replacement parts<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>This documentation helps prevent a common mistake: approving the camera but failing to verify the rest of the certified installation path.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How can SWGJ CAMERA support hazardous-area surveillance?<\/h2>\n\n\n\n<p>SWGJ CAMERA presents a product portfolio covering explosion-proof PTZ, bullet, dome, thermal and accessory categories. Its product pages also connect these categories to oil and gas, petrochemical, coal, marine, chemical, grain-storage and other industrial applications.<\/p>\n\n\n\n<p>For a project inquiry, provide:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Hazardous-area classification<\/li>\n\n\n\n<li>Gas or dust group and temperature class<\/li>\n\n\n\n<li>Site location and environmental conditions<\/li>\n\n\n\n<li>Monitoring target and required distance<\/li>\n\n\n\n<li>Fixed, PTZ, dome or thermal preference<\/li>\n\n\n\n<li>Power and network availability<\/li>\n\n\n\n<li>Mounting and cable-entry requirements<\/li>\n\n\n\n<li>Required certificates and documentation<\/li>\n\n\n\n<li>Recording, alarm and remote-access requirements<\/li>\n<\/ul>\n\n\n\n<p>A supplier can give a more reliable recommendation when the inquiry contains engineering information rather than only a request for \u201can explosion-proof camera.\u201d<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Explosion-proof camera selection checklist<\/h2>\n\n\n\n<p>Before purchase or approval, confirm:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The camera is required by the hazardous-area assessment.<\/li>\n\n\n\n<li>The exact model and certificate match.<\/li>\n\n\n\n<li>The protection marking is appropriate for the gas or dust environment.<\/li>\n\n\n\n<li>The temperature class and ambient range are suitable.<\/li>\n\n\n\n<li>The camera type matches the viewing objective.<\/li>\n\n\n\n<li>Lens, zoom and night-vision performance match the target distance.<\/li>\n\n\n\n<li>The housing material matches corrosion and mechanical conditions.<\/li>\n\n\n\n<li>The power, network and recording systems are compatible.<\/li>\n\n\n\n<li>Junction boxes, flexible tubes, glands and brackets are included in the review.<\/li>\n\n\n\n<li>Installation and maintenance instructions are available.<\/li>\n\n\n\n<li>Certification documents are checked before site commissioning.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently asked questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Is an IP68 camera automatically explosion-proof?<\/h3>\n\n\n\n<p>No. IP68 describes resistance to water and dust under defined test conditions. Explosion-proof suitability requires the appropriate protection concept, certification marking, equipment scope and installation conditions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the difference between an explosion-proof PTZ and a fixed camera?<\/h3>\n\n\n\n<p>A PTZ camera can change direction and use zoom for wider-area or long-distance inspection. A fixed camera continuously observes a defined target and may be easier to commission for a stable view. Many large facilities use both types.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Is an ATEX camera the same as an IECEx camera?<\/h3>\n\n\n\n<p>They are different certification systems with different documentation and market contexts. ATEX is an EU legal framework for equipment and protective systems intended for potentially explosive atmospheres. IECEx is an international conformity-assessment system based on relevant standards. The exact certificate and market requirements must be checked for the project.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can a normal outdoor camera be installed in Zone 1 or Zone 2?<\/h3>\n\n\n\n<p>Not simply because it is weatherproof. The equipment must be suitable for the classified area and covered by the required certification and installation design. A qualified hazardous-area engineer should approve the selection.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Should I choose 304 or 316 stainless steel?<\/h3>\n\n\n\n<p>The choice depends on corrosion exposure, marine conditions, chemicals, cleaning procedures and the exact product documentation. The material option should be confirmed for the selected model and should not be treated as a substitute for certification.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Does a thermal camera detect gas leaks?<\/h3>\n\n\n\n<p>Not necessarily. A thermal camera can support heat-pattern or temperature-anomaly monitoring, but gas-leak detection depends on the gas, sensor principle, algorithm, calibration, installation and project evidence. Confirm the exact function with the product documentation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What accessories are normally reviewed with the camera?<\/h3>\n\n\n\n<p>The review may include brackets, cable glands, junction boxes, flexible tubes, conduit, grounding, power equipment and network devices. Compatibility and certification must be checked as a complete installation path.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What should I send when requesting an explosion-proof camera quotation?<\/h3>\n\n\n\n<p>Send the hazardous-area classification, gas or dust group, temperature class, site environment, monitoring distance, target object, preferred camera type, power and network conditions, installation drawing and required certificates. This gives the supplier enough information to recommend a project-compatible configuration.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Sources and SWGJ CAMERA product links<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.swgjcamera.com\/fr\/\" target=\"_blank\" rel=\"noreferrer noopener\">SWGJ CAMERA Homepage<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-ptz-camera\/infrared-ptz\/\" target=\"_blank\" rel=\"noreferrer noopener\">Explosion-Proof Infrared PTZ Camera<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-bullet-camera\/fixed-lens\/\" target=\"_blank\" rel=\"noreferrer noopener\">Explosion-Proof Fixed Lens Camera<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-dome-camera\/fixed-dome\/\" target=\"_blank\" rel=\"noreferrer noopener\">Explosion Proof Fixed Dome<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-ptz-camera\/dual-sensor-thermal\/\" target=\"_blank\" rel=\"noreferrer noopener\">Explosion Proof Dual Sensor Thermal Camera<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-accessories\/junction-box\/\" target=\"_blank\" rel=\"noreferrer noopener\">Certified Junction Box<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.swgjcamera.com\/fr\/products\/explosion-proof-accessories\/flexible-tube\/\" target=\"_blank\" rel=\"noreferrer noopener\">Flameproof Flexible Tube<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/eur-lex.europa.eu\/eli\/dir\/2014\/34\/oj\/eng\" target=\"_blank\" rel=\"noreferrer noopener\">ATEX Directive 2014\/34\/EU<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.iecex.com\/certified-equipment-scheme\/overview\/\" target=\"_blank\" rel=\"noreferrer noopener\">IECEx Certified Equipment Scheme<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>What is an explosion-proof camera? An explosion-proof camera is surveillance equipment designed for use in locations where flammable gas, vapor, dust or other combustible material may create an explosive atmosphere. Its protective construction is intended to prevent the equipment from becoming an ignition source under the conditions covered by its certification and installation method. This [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2448,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-2587","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Choose an Explosion-Proof Camera for Hazardous Areas - SWGJ | Explosion-Proof Camera Manufacturer<\/title>\n<meta name=\"description\" content=\"Learn how to choose an explosion-proof camera for oil and gas, chemical, mining and other hazardous areas. Compare PTZ, fixed bullet, dome and thermal cameras, then verify certification, installation and project compatibility.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.swgjcamera.com\/fr\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Choose an Explosion-Proof Camera for Hazardous Areas - SWGJ | Explosion-Proof Camera Manufacturer\" \/>\n<meta property=\"og:description\" content=\"Learn how to choose an explosion-proof camera for oil and gas, chemical, mining and other hazardous areas. Compare PTZ, fixed bullet, dome and thermal cameras, then verify certification, installation and project compatibility.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.swgjcamera.com\/fr\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/\" \/>\n<meta property=\"og:site_name\" content=\"SWGJ | Explosion-Proof Camera Manufacturer\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-16T07:36:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-16T07:36:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.swgjcamera.com\/wp-content\/uploads\/2026\/04\/1-4.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1536\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"camera@hikwifi.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"camera@hikwifi.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/\"},\"author\":{\"name\":\"camera@hikwifi.com\",\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/#\\\/schema\\\/person\\\/8d40d782a83e6238bdc68b715a050738\"},\"headline\":\"How to Choose an Explosion-Proof Camera for Hazardous Areas\",\"datePublished\":\"2026-10-16T07:36:41+00:00\",\"dateModified\":\"2026-10-16T07:36:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/\"},\"wordCount\":2260,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.swgjcamera.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/1-4.webp\",\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/\",\"url\":\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/\",\"name\":\"How to Choose an Explosion-Proof Camera for Hazardous Areas - SWGJ | Explosion-Proof Camera Manufacturer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.swgjcamera.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/1-4.webp\",\"datePublished\":\"2026-10-16T07:36:41+00:00\",\"dateModified\":\"2026-10-16T07:36:43+00:00\",\"description\":\"Learn how to choose an explosion-proof camera for oil and gas, chemical, mining and other hazardous areas. Compare PTZ, fixed bullet, dome and thermal cameras, then verify certification, installation and project compatibility.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.swgjcamera.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/1-4.webp\",\"contentUrl\":\"https:\\\/\\\/www.swgjcamera.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/1-4.webp\",\"width\":1536,\"height\":1024,\"caption\":\"Aerospace\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"HOME\",\"item\":\"https:\\\/\\\/www.swgjcamera.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Choose an Explosion-Proof Camera for Hazardous Areas\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/#website\",\"url\":\"https:\\\/\\\/www.swgjcamera.com\\\/\",\"name\":\"SWGJ | Explosion-Proof Camera Manufacturer\",\"description\":\"Industrial-grade thermal PTZ and rugged surveillance solutions for extreme environments.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.swgjcamera.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/#organization\",\"name\":\"SWGJ | Explosion-Proof Camera Manufacturer\",\"url\":\"https:\\\/\\\/www.swgjcamera.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.swgjcamera.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/350-100.png\",\"contentUrl\":\"https:\\\/\\\/www.swgjcamera.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/350-100.png\",\"width\":350,\"height\":100,\"caption\":\"SWGJ | Explosion-Proof Camera Manufacturer\"},\"image\":{\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.swgjcamera.com\\\/#\\\/schema\\\/person\\\/8d40d782a83e6238bdc68b715a050738\",\"name\":\"camera@hikwifi.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f4622da74a05aa14e6388a680a06d224d8392720e813b8173abaff86887d861b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f4622da74a05aa14e6388a680a06d224d8392720e813b8173abaff86887d861b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f4622da74a05aa14e6388a680a06d224d8392720e813b8173abaff86887d861b?s=96&d=mm&r=g\",\"caption\":\"camera@hikwifi.com\"},\"sameAs\":[\"https:\\\/\\\/swgjcamera.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Choose an Explosion-Proof Camera for Hazardous Areas - SWGJ | Explosion-Proof Camera Manufacturer","description":"Learn how to choose an explosion-proof camera for oil and gas, chemical, mining and other hazardous areas. Compare PTZ, fixed bullet, dome and thermal cameras, then verify certification, installation and project compatibility.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.swgjcamera.com\/fr\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/","og_locale":"fr_FR","og_type":"article","og_title":"How to Choose an Explosion-Proof Camera for Hazardous Areas - SWGJ | Explosion-Proof Camera Manufacturer","og_description":"Learn how to choose an explosion-proof camera for oil and gas, chemical, mining and other hazardous areas. Compare PTZ, fixed bullet, dome and thermal cameras, then verify certification, installation and project compatibility.","og_url":"https:\/\/www.swgjcamera.com\/fr\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/","og_site_name":"SWGJ | Explosion-Proof Camera Manufacturer","article_published_time":"2026-10-16T07:36:41+00:00","article_modified_time":"2026-10-16T07:36:43+00:00","og_image":[{"width":1536,"height":1024,"url":"https:\/\/www.swgjcamera.com\/wp-content\/uploads\/2026\/04\/1-4.webp","type":"image\/webp"}],"author":"camera@hikwifi.com","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"camera@hikwifi.com","Dur\u00e9e de lecture estim\u00e9e":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/#article","isPartOf":{"@id":"https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/"},"author":{"name":"camera@hikwifi.com","@id":"https:\/\/www.swgjcamera.com\/#\/schema\/person\/8d40d782a83e6238bdc68b715a050738"},"headline":"How to Choose an Explosion-Proof Camera for Hazardous Areas","datePublished":"2026-10-16T07:36:41+00:00","dateModified":"2026-10-16T07:36:43+00:00","mainEntityOfPage":{"@id":"https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/"},"wordCount":2260,"commentCount":0,"publisher":{"@id":"https:\/\/www.swgjcamera.com\/#organization"},"image":{"@id":"https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/#primaryimage"},"thumbnailUrl":"https:\/\/www.swgjcamera.com\/wp-content\/uploads\/2026\/04\/1-4.webp","articleSection":["Uncategorized"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/","url":"https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/","name":"How to Choose an Explosion-Proof Camera for Hazardous Areas - SWGJ | Explosion-Proof Camera Manufacturer","isPartOf":{"@id":"https:\/\/www.swgjcamera.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/#primaryimage"},"image":{"@id":"https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/#primaryimage"},"thumbnailUrl":"https:\/\/www.swgjcamera.com\/wp-content\/uploads\/2026\/04\/1-4.webp","datePublished":"2026-10-16T07:36:41+00:00","dateModified":"2026-10-16T07:36:43+00:00","description":"Learn how to choose an explosion-proof camera for oil and gas, chemical, mining and other hazardous areas. Compare PTZ, fixed bullet, dome and thermal cameras, then verify certification, installation and project compatibility.","breadcrumb":{"@id":"https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/#primaryimage","url":"https:\/\/www.swgjcamera.com\/wp-content\/uploads\/2026\/04\/1-4.webp","contentUrl":"https:\/\/www.swgjcamera.com\/wp-content\/uploads\/2026\/04\/1-4.webp","width":1536,"height":1024,"caption":"Aerospace"},{"@type":"BreadcrumbList","@id":"https:\/\/www.swgjcamera.com\/how-to-choose-an-explosion-proof-camera-for-hazardous-areas\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"HOME","item":"https:\/\/www.swgjcamera.com\/"},{"@type":"ListItem","position":2,"name":"How to Choose an Explosion-Proof Camera for Hazardous Areas"}]},{"@type":"WebSite","@id":"https:\/\/www.swgjcamera.com\/#website","url":"https:\/\/www.swgjcamera.com\/","name":"SWGJ | Explosion-Proof Camera Manufacturer","description":"Industrial-grade thermal PTZ and rugged surveillance solutions for extreme environments.","publisher":{"@id":"https:\/\/www.swgjcamera.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.swgjcamera.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.swgjcamera.com\/#organization","name":"SWGJ | Explosion-Proof Camera Manufacturer","url":"https:\/\/www.swgjcamera.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.swgjcamera.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.swgjcamera.com\/wp-content\/uploads\/2026\/01\/350-100.png","contentUrl":"https:\/\/www.swgjcamera.com\/wp-content\/uploads\/2026\/01\/350-100.png","width":350,"height":100,"caption":"SWGJ | Explosion-Proof Camera Manufacturer"},"image":{"@id":"https:\/\/www.swgjcamera.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.swgjcamera.com\/#\/schema\/person\/8d40d782a83e6238bdc68b715a050738","name":"camera@hikwifi.com","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/f4622da74a05aa14e6388a680a06d224d8392720e813b8173abaff86887d861b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f4622da74a05aa14e6388a680a06d224d8392720e813b8173abaff86887d861b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f4622da74a05aa14e6388a680a06d224d8392720e813b8173abaff86887d861b?s=96&d=mm&r=g","caption":"camera@hikwifi.com"},"sameAs":["https:\/\/swgjcamera.com"]}]}},"_links":{"self":[{"href":"https:\/\/www.swgjcamera.com\/fr\/wp-json\/wp\/v2\/posts\/2587","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.swgjcamera.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.swgjcamera.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.swgjcamera.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.swgjcamera.com\/fr\/wp-json\/wp\/v2\/comments?post=2587"}],"version-history":[{"count":0,"href":"https:\/\/www.swgjcamera.com\/fr\/wp-json\/wp\/v2\/posts\/2587\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.swgjcamera.com\/fr\/wp-json\/wp\/v2\/media\/2448"}],"wp:attachment":[{"href":"https:\/\/www.swgjcamera.com\/fr\/wp-json\/wp\/v2\/media?parent=2587"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.swgjcamera.com\/fr\/wp-json\/wp\/v2\/categories?post=2587"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.swgjcamera.com\/fr\/wp-json\/wp\/v2\/tags?post=2587"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}